ISO 7507-3:2006Published

Petroleum and liquid petroleum products — Calibration of vertical cylindrical tanks — Part 3: Optical-triangulation method

Pétrole et produits pétroliers liquides — Jaugeage des réservoirs cylindriques verticaux — Partie 3: Méthode par triangulation optique

Abstract / scope

ISO 7507-3:2006 specifies a calibration procedure for application to tanks above 8 m in diameter with cylindrical courses that are substantially vertical. It provides a method for determining the volumetric quantity contained within a tank at gauged liquid levels. The measurements required to determine the radius are made either internally or externally. The external method is applicable only to tanks that are free of insulation.

ISO 7507-3:2006 is suitable for tanks tilted up to a 3 % deviation from the vertical, provided that a correction is applied for the measured tilt as described in ISO 7507-1.

Life cycle

Replaces

ISO 7507-3:1993WithdrawnPetroleum and liquid petroleum products — Calibration of vertical cylindrical tanks — Part 3: Optical-triangulation methodInternational Standard · Published 22 Jul 1993 · ISO/TC 28/SC 2