ISO 16975-3:2017Published

Respiratory protective devices — Selection, use and maintenance — Part 3: Fit-testing procedures

Appareils de protection respiratoire — Choix, utilisation et entretien — Partie 3: Modes opératoires d'essais d'ajustement

A new edition is under development: ISO/AWI 16975-3.

Abstract / scope

ISO 16975-3:2017 specifies guidance on how to conduct fit testing of tight-fitting respiratory protective device (RPD) and on appropriate methods to be used. Fit testing is only one element of a complete RPD programme. The intention of fit testing is to evaluate the effectiveness of the seal between the wearer's face and the respiratory interface (RI). A complete RPD programme is defined in ISO/TS 16975‑1.

ISO 16975-3:2017 specifies requirements for conducting RPD fit testing and includes

- qualifications/competences of fit-test operators,

- specific fit-testing procedures,

- interpretation of fit-test results, and

- record keeping.

A fit test is not required for escape-only RPD.

Life cycle

Replaced by

ISO/CD 16975-3Deleted (project abandoned)Respiratory protective devices — Selection, use and maintenance — Part 3: Fit-testing proceduresInternational Standard · ISO/TC 94/SC 15ISO/AWI 16975-3Under developmentRespiratory protective devices — Selection, use and maintenance — Part 3: Fit-testing proceduresInternational Standard · ISO/TC 94/SC 15