ISO 2431:1993Withdrawn

Paints and varnishes — Determination of flow time by use of flow cups

Peintures et vernis — Détermination du temps d'écoulement au moyen de coupes d'écoulement

Abstract / scope

Four flow cups of similar dimensions, but having orifice diameters of 3 mm, 4 mm, 5 mm and 6 mm, are specified, The method for their calibration is given. Flow time may be used to control consistency (a method for the adjustment of paints to the correct application consistency at the application temperature is described in Annex A). The method is limited to testing materials for which the breakpoint of the flow from the orifice of the flow cup can be determined with certainty. This point is difficult to determine and reproduce for materials with flow times in excess of 100 s.

Life cycle

Amendments & corrigenda

ISO 2431:1993/Cor 1:1994WithdrawnPaints and varnishes — Determination of flow time by use of flow cups — Technical Corrigendum 1International Standard · Published 23 Jun 1994 · ISO/TC 35/SC 9ISO 2431:1993/Cor 2:1999WithdrawnPaints and varnishes — Determination of flow time by use of flow cups — Technical Corrigendum 2International Standard · Published 25 Mar 1999 · ISO/TC 35/SC 9

Replaces

ISO 2431:1980WithdrawnPaint and varnishes — Determination of flow time by use of flow cupsInternational Standard · Published 1 Oct 1980 · ISO/TC 35ISO 2431:1984WithdrawnPaints and varnishes — Determination of flow time by use of flow cupsInternational Standard · Published 1 Aug 1984 · ISO/TC 35/SC 9

Replaced by

ISO 2431:2011WithdrawnPaints and varnishes — Determination of flow time by use of flow cupsInternational Standard · Published 10 Nov 2011 · ISO/TC 35/SC 9