ISO 3680:1983Withdrawn

Paints, varnishes, petroleum and related products — Flash/no flash test — Rapid equilibrium method

Peintures, vernis, produits pétroliers et assimilés — Essai de point d'éclair par tout ou rien — Méthode rapide à l'équilibre

Abstract / scope

The principle consists in heating the test portion in the specified apparatus. The ignition trial is carried out after the test portion has been maintained under equilibrium conditions for 60 s at the selected equilibrium temperature. This procedure ensures that air/vapour space above the test portion has attained the saturation concentration of flammable vapour before the ignition trial is performed. This method of test does not determine the flashpoint of the product under test, but merely its behaviour at the selected equilibrium temperature as may be required to comply with or regulations.

Life cycle

Replaced by

ISO 3680:2004WithdrawnDetermination of flash/no flash — Rapid equilibrium closed cup methodInternational Standard · Published 16 Mar 2004 · ISO/TC 28